Product Details:
Minimum Order Quantity | 40 Piece |
Interface | Inbuilt |
Usage | Laboratory |
Temperature Range | -30C to +70C |
Case Material | Polycarbonate |
Typical Battery Life | 1-3 years,depends on recording interval |
Use DataLoggers | Single use |
Sensors | NTC internal |
Monitoring your cold chain have become very easy with most economical, super compact single use data logger Tempnote Lite.
Tempnote data loggers are extremely engineered for seamless performance to monitor door to door cold chain shipments. Tempnote data loggers are pre-configured and ready to use device with 2 years of shelf life.
Moreover, it also can be set to user specific requirement like 2C-8C, 15C-25C, -25C to -15C or any customize temperature range, sampling interval and start delay by our TempLoop software.
Tempnote dataloggers auto generates PDF report without requiring additional cable/hardware or software. PDF report contains graphical as well as tabular data interpretation. Its first page contains summary of entire journey, start & stop date/time, Max/Min/Avg./MKT temperature, and excursion details. Tempnote Lite offers best in its class performance for cold chain monitoring for temperature sensitive shipments.
Tempnote Lite is factory configured with default settings. However, customer can change default setting to their specific requirement and repack it in the provided double locks waterproof plastic sleeve. Following parameters can be set by our Temploop software.
Product Details:
Usage/Application | Cold Storages |
Parameter To Be Monitored | Temperature |
Export Of Data | |
Display | LCD |
Brand | Tempsen |
Memory | 14000 Readings |
Warranty | 1 Year |
Software | TempCentre Data Management Free download |
Model | TEMPOD TD90S |
Certificates | CE,DO160G,RoHS,ISO9001 2008 |
Product Details:
Minimum Order Quantity | 1 Unit |
Model Number | EBI 310 |
Accuracy | 0.2C (-30C..+30C). 0.5C for the remainder |
Memory | 120,000 measurements |
Power Resource | Internal Battery |
Recorder StartUp | Automatic, Manually |
Resolution | 0.1C |
Sampling Frequency | 1 Mins to 60 Mins |
Security | Embedded PDF |
Typical Battery Life | 2 Yrs/ Replaceable |
Warranty | 1 Year manufacturer warranty |
Maximum start delay | 72 h |
Housing material | Polycarbonate |
Due to its wide-ranging accessories, the EBI 310 becomes an all-rounder. It can be used to measure the temperature of liquid nitrogen, dry ice, to monitor blood or blood plasma, vaccines and medicine as well as control ovens and roasting houses.
The EBI 310 offers the option of an easy alarm management consisting of higher and lower limit, and an alarm delay time or a 6 stepped alarm management. This more effective alarm management offers the possibility of preparing the logger during the programming in a way that the employee has a decision support if the executed measurement has been evaluated positive or negative. This is especially important during the transport of vaccines. All EBI 310 data loggers can run with an internal sensor and the possible external probes at the same time.
The sectors in which you can use the EBI 310 TE can vary. Due to its external probe, the logger can measure an area of -200 °C to +250 °C and covers a wide-ranging field of measurement activities and applications. For example, the EBI 310 TE logger can measure the room temperature with its internal probe and with its external probe it can measure the temperature in liquid nitrogen. But the logger can also be used during validation, when the external probe is placed punctually in the room you validate in.
The EBI 310 DI has been developed to use in dry ice or to measure refrigerators of -80 °C. He can record the temperature for 100 hours in -80 °C and is therefore suitable to measure in refrigerators or cooling rooms with -80 °C.
You can use the EBI 310 TX where more than one external probe is necessary. With his 2 connectable external probes with various needle or cable lengths or needle diameter he offers the most diversity. You can execute measurement activities in roasting houses or ovens using the probes.
The EBI 310 TH with an external humidity probe can be used in rooms, in which the relative air humidity and the temperature must be monitored, for example in laboratories or during the validation. The EBI 310 works with a customary battery, which you can change on your own.
Product Details:
Minimum Order Quantity | 1 Unit |
Brand | LogTag |
Model Number | TRID-30 |
Temperature Range | -30C to 60C |
Size | 86mm(H)x54.5mm(W)x8.6mm(T) |
Storage Temprature | Room Temperature |
Recorder StartUp | Automatic Push Button |
Case Material | Polycarbonate |
Connection Interface | Interface Cradle |
Memory | 7770 Readings |
Power Source | 3V Li-Mg Battery |
Sampling Frequency | Adjustable, 30 seconds to several hours |
Time date | picks from PC clock |
Typical Battery Life | 1 years (depending on usage) |
The LogTag® TRID30-7 temperature logger features a display together with data logging function storing up to 7770 temperature readings. Statistical temperature and duration readings for up to 30 days can be reviewed on the display. The visual display of current temperature and previous alarms is an important feature in “static” applications such as cool rooms and refrigerators.
The TRID30-7 can also be used in transit applications where direct readout of the statistical data is required without use of a computer or readout device. The display arrangement is designed to show ‘at a glance’ if temperature violations have occurred during the current day and up to the previous 29 days. The display also shows the current temperature reading, the current time, recording status and battery status. Details of any excursions can be checked directly by inspecting the statistics history on the loggers display or in more detail by downloading the logged data.
If a reading outside the pre-set “Alarm” limits is recorded at any time, a “day alarm indicator” appears on the display. Logged data can be downloaded via a standard LogTag® Interface to the companion software LogTag® Analyzer which provides facilities for displaying data in chart, table or statistical formats and allows electronic archiving, export or transmission of the data in support of sophisticated data management systems.
Product Details:
Minimum Order Quantity | 10 Piece |
Interface | Inbuilt |
Brand | Elitech |
Model | LogET 8 |
Usage | Laboratory |
Memory | 16000 Readings |
Ip Rating | IP67 |
Data Loggers Type | TD |
Use Data Loggers | MU |
Sensors | Internal |
Liquid Crystal Display | Multi Functional LCD |
Case Material | Polycarbonate |
Typical Battery Life | 2 years |
Accessing recorded data with our LogEt 8 life science multi-use PDF temperature data logger is simple. Simply plug it to a computer via a USB port to access a detailed report in PDF format. Elitech LogEt 8 life science multi-use PDF temperature data logger takes no more than 4 minutes to process the data logger report.
Every LogEt 8 life science multi-use PDF temperature data logger has easy to configure 4 different alarm settings, with Elitech advanced Mean Kinetic Temperature (MKT).
Product Details:
BRAND | TEMPSEN |
TYPE | MULTI USE |
MEASURES | TEMPERATURE |
TEMPERATURE RANGE | -100 DegreeC TO +70 DegreeC |
TEMPERATURE ACCURACY | 0.5 DegreeC |
TEMPERATURE RESOLUTIONS | 0.1 DegreeC |
SENSOR | EXTERNAL SENSOR |
SAMPLING MEMORY | 28800 VALUES |
CONFIGURATION | USER CONFIGURABLE |
REPORT FORMAT | CSV, PDF |
AUTO GENERATES PDF REPORT | YES |
SOFTWARE | FREE, FDA 21 CFR PART 11 |
BATTERY | REPLACEABLE |
SHELF LIFE | 2 YEARS |
Product Details:
Model Name/Number | TH32 |
Usage/Application | Cold Storages |
Parameter To Be Monitored | Humidity |
Export Of Data | |
No. Of Channels | Single Channel |
Product Details:
Minimum Order Quantity | 1 Unit |
Interface | External |
Brand | LogTag |
Usage | Laboratory |
Memory | 8000 Readings |
Temperature Range | -80C to +40C |
Ip Rating | IP65 |
Humidity Range | NA |
DataLoggers Type | TD |
Use DataLoggers | MU |
Sensors | Internal |
Sensor Response Time | Typically less than 5 minutes T90 in moving air 1 m/s |
Sampling Frequency | 1 min to 60 min OR 1 hr to 18 hrs |
Time date | picks from PC clock |
Power Resource | 3V Low Temp Chemistry Lithium Battery |
Case Material | Polycarbonate |
Storage Temprature | Room Temperature |
Typical Battery Life | 1000 Hours -80 deg C |
Recorder StartUp | Automatic Push Button |
Product Details:
Minimum Order Quantity | 5 Piece |
Brand | Escort |
Memory | 16000 Readings |
Warranty | 1 year |
Temperature Range | -40 deg C to +70 deg C (-40 deg F to +158 deg F) |
Weight | 70 grams |
Resolution | 0.1 deg C (0.1 deg F) |
Product Code | MU-IN-D-16-L |
Use Data Loggers | MU |
Data Loggers Type | TD |
Sensor Response Time | T90 of 20 minutes in moving air |
Sampling Frequency | 5 seconds to 18 hours |
Power Resource | 3.0V user replaceable |
Size | 83 x 57 x 17mm |
Case Material | Polycarbonate/ABS |
Typical Battery Life | 1-2 years |
Recorder StartUp | Push button and/or timer |
The Escort iMiniPlus PDF data logger is the ideal instrument for monitoring temperature sensitive shipments to distant destinations where proprietary software is unavailable.
The Escort iMiniPlus PDF data logger uses a USB mini B to USB type A cable* (supplied with PDF logger) or small USB adaptor for computer communications. It is a true Plug and Play device. When the logger is connected, the computer automatically recognizes the logger as a Mass Storage Device and PDF report can be viewed with two other binary files. Please allow sufficient time for installation (5 to 30 seconds).
Every data logger is supplied with a simple USB to USB cable for PC connection and travels with the logger in the consignment. Report generation includes a summary of transport condition, time spent out of specification and trip statistics. In addition the report provides date, time and temperature of all readings plus a graph of the temperature of the trip. The PDF report can be validated by Console software by emailing the PDF report and binary files to the Supplier thus meeting the requirements for 21 CFR Part11.